Table of Contents



NAME

tixControl - Create and manipulate tixControl widgets

SYNOPSIS

tixControl pathName ?options?

SUPER-CLASS

The TixControl class is derived from the TixLabelWidget class and inherits all the commands, options and subwidgets of its super-class.

STANDARD OPTIONS

The Control widget supports all the standard options of a frame widget. See the options(n) manual entry for details on the standard options.

WIDGET-SPECIFIC OPTIONS

Name:        allowEmpty
Class:        AllowEmpty
Switch:        -allowempty

Specifies whether the Control widget should allow the empty string
as a valid input.

Name:        autorepeat
Class:        AutoRepeat
Switch:        -autorepeat

Specifies whether the Control widget should have autorepeat behavior.
If set to be "true", the value of the Control widget will be automatically incremented or decremented when the user holds down the mouse button over the arrow buttons. Only values "true" and "false" will be recognized.

Name:        command
Class:        Command
Switch:        -command

Specifies the command to be called when the -value option of
the Control widget is changed. The command will be called with one arguments -- the new value of the Control widget.

Name:        decrCmd
Class:        DecrCmd
Switch:        -decrcmd

Specifies a TCL command to be called when the the user presses the
down-arrow button subwidget. This command is called with one parameter -- the current -value of this Control widget. This command is to decrement this value by one step, according to its own definition of "decrement", and return the decremented value, which will be stored in the -value of this Control widget.

Name:        disableCallback
Class:        DisableCallback
Switch:        -disablecallback

A boolean value indicating whether callbacks should be disabled. When
set to true, the TCL command specified by the -command option is not executed when the -value of the Control widget changes.

Name:        disableForeground
Class:        DisableForeground
Switch:        -disableforeground

The foreground color to use for of the entry subwidget when the
Control widget is disabled.

Name:        incrCmd
Class:        IncrCmd
Switch:        -incrcmd

Specifies a TCL command to be called when the the user presses the
up-arrow button subwidget. This command is called with one parameter -- the current -value of this Control widget. This command is to increment this value by one step, according to its own definition of "increment", and return the incremented value, which will be stored in the -value of this Control widget.

Name:        initwait
Class:        Initwait
Switch:        -initwait

Specifies how long the Control widget should wait initially before
it starts to automatically increment or decrement its value in the autorepeat mode. In milliseconds.

Name:        integer
Class:        Integer
Switch:        -integer

A Boolean value specifying whether only integer numbers are accepted.

Name:        label
Class:        Label
Switch:        -label

Specifies the string to display as the label of this Control widget.

Name:        labelSide
Class:        LabelSide
Switch:        -labelside

Specifies where the label should be displayed relative to the entry
subwidget. Valid options are: top, left, right, bottom, none or acrosstop.

Name:        max
Class:        Max
Switch:        -max
Alias:        -ulimit

Specifies the upper limit of the value of the Control widget. When set
to empty string, the Control widget has no upper limit.

Name:        min
Class:        Min
Switch:        -min
Alias:        -llimit

Specifies the lower limit of the value of the Control widget.When set
to empty string, the Control widget has no lower limit.

Name:        repeatRate
Class:        RepeatRate
Switch:        -repeatrate

Specifies how often the value of the Control widget should be
incremented or decremented when it is in the autorepeat mode. In milliseconds.

Name:        selectMode
Class:        SelectMode
Switch:        -selectmode

Specifies how the Control widget should react to <KeyPress>
events. When set to "immediate", any user keyboard inputs will immediately change the -value option. When set to "normal", the user keyboard inputs will be copied to the -value option only if the <Return> key is pressed or the keyboard focus is changed. The use of the immediate mode is discouraged. For effective use of the Control widget, one should use the normal mode together with the update widget command (see below).

Name:        state
Class:        State
Switch:        -state

Specifies the whether the Control widget is normal or
disabled. Only the values "normal" and "disabled" are recognized.

Name:        step
Class:        Step
Switch:        -step

Specifies by how much the value of the Control widget should be
incremented or decrmented when the user press the arrow buttons.

Name:        validateCmd
Class:        ValidateCmd
Switch:        -validatecmd

Specifies a TCL command to be called when the -value of the
Control widget is about to change. This command is called with one parameter -- the new -value entered by the user. This command is to validate this new value by returning a value it deems valid.

Name:        value
Class:        Value
Switch:        -value

Specifies the value of the Control widget.

Name:        variable
Class:        Variable
Switch:        -variable

Specifies the global variable in which the value of the
Control widget should be stored. The value of the Control widget will be automatically updated when this variable is changed.

SUBWIDGETS

Name:        decr
Class:        Button

The down arrow button.

Name:        entry
Class:        Entry

The entry that shows the value of this Control widget.

Name:        incr
Class:        Button

The up arrow button.

Name:        label
Class:        Label

The label subwidget.



DESCRIPTION

The tixControl command creates a new window (given by the pathName argument) and makes it into a Control widget. Additional options, described above, may be specified on the command line or in the option database to configure aspects of the Control widget such as its cursor and relief.

The Control widget is also known as the SpinBox widget. It is generally used to control a value. The user can adjust the value by pressing the two arrow buttons or by entering the value directly into the entry. The new value will be checked against the user-defined upper and lower limits.

WIDGET COMMANDS

The tixControl command creates a new Tcl command whose name is the same as the path name of the Control widget's window. This command may be used to invoke various operations on the widget. It has the following general form:


pathName option ?arg arg ...?

PathName is the name of the command, which is the same as the Control widget's path name. Option and the args determine the exact behavior of the command. The following commands are possible for Control widgets:

pathName cget option
Returns the current value of the configuration option given by option. Option may have any of the values accepted by the tixControl command.
pathName configure ?option? ?value option value ...?
Query or modify the configuration options of the widget. If no option is specified, returns a list describing all of the available options for pathName (see Tk_ConfigureInfo for information on the format of this list). If option is specified with no value, then the command returns a list describing the one named option (this list will be identical to the corresponding sublist of the value returned if no option is specified). If one or more option-value pairs are specified, then the command modifies the given widget option(s) to have the given value(s); in this case the command returns an empty string. Option may have any of the values accepted by the tixControl command.
pathName decr
Decrements the value of the Control widget by the step specified by the -step option.
pathName incr
Increments the value of the Control widget by the step specified by the -step option.
pathName invoke
Causes the command specified by the -command option to be invoked.
pathName update
If the user has modified the entry using keyboard inputs, the update command will update the -value of this Control widget. When the Control widget's -selectmode option is set to "normal", one should call the update command on this widget before examining its -value option. This command has no effect in if the -selectmode option is set to "immediate".
pathName subwidget name ?args?
When no options are given, this command returns the pathname of the subwidget of the specified name.

When options are given, the widget command of the specified subwidget will be called with these options.

BINDINGS

When the user presses the up/down arrow buttons (or press the <Up> and <Down> arrow keys on the keyboard), the value of the tixControl widget is adjusted according to the -validatecmd, -incrcmd, -decrcmd, -step, -max and -min options.

KEYWORDS

Tix(n)


Table of Contents


www.fiveanddime.net

Google
Web www.fiveanddime.net